This project has moved. For the latest updates, please go here.
1

Closed

Behavior Option for Tab Switching On DataStreamExceptions

description

Current Behavior: While observing the Graph tab, On receiving a IEEE C37.118-2005 message with a CRC error, the tab is changed to the Messages tab.
Proposed Change: Provide an option to enable/disable this behavior to permit continuous Graph viewing even if some of the data messages are garbled.

file attachments

Closed Jan 21, 2011 at 10:38 PM by ajstadlin
Reference: Change Set # 67215

comments

ajstadlin wrote Jan 21, 2011 at 8:52 PM

Propose to change the following exception handler to *.Selected = Behavior_Option
Private Sub DataStreamException(ByVal ex As System.Exception)
    AppendStatusMessage("Exception: " & ex.Message)
    TabControlChart.Tabs(ChartTabs.Messages).Selected = True
End Sub

wrote Jan 21, 2011 at 9:22 PM

ajstadlin wrote Jan 21, 2011 at 9:22 PM

I added an application setting for ShowMessagesTabOnDataException and changed the main form DataStreamException handler as follows:

Private Sub DataStreamException(ByVal ex As System.Exception)
AppendStatusMessage("Exception: " & ex.Message)
If m_applicationSettings.ShowMessagesTabOnDataException Then
    TabControlChart.Tabs(ChartTabs.Messages).Selected = True
End If
End Sub

wrote Jan 21, 2011 at 10:18 PM

wrote Jan 21, 2011 at 10:38 PM

wrote Feb 14, 2013 at 1:29 AM